SERVICE SPECIFICATIONS


Item
Standard value
Limit
Alternator output line voltage drop (at 30 A) V
-
Maximum 0.3
Output current
-
70 % of normal output current
Regulated voltage ambient temperature at voltage regulator V <Except vehicles for Thailand>
-20°C
14.0 - 15.1
-
20°C
13.7 - 14.6
-
60°C
13.2 - 14.3
-
80°C
12.9 - 14.1
-
Regulated voltage ambient temperature at voltage regulator V <Vehicles for Thailand>
-20°C
14.2 - 15.4
-
20°C
13.9 - 14.9
-
60°C
13.4 - 14.6
-
80°C
13.1 - 14.5
-