INITIALISATION PROCEDURE FOR CVT LEARNED VALUE



AIM


After the CVT assembly is replaced, learned values must be initialised. The initialisation procedure is as below.

INITIALISATION PROCEDURE


1.Move the selector lever to the P range and turn the ignition switch to the LOCK (OFF) position. Then, connect M.U.T.-III to the diagnosis connector.
2.Turn the ignition switch to the ON position, and then move the selector lever to the R range.
3.Depress the accelerator pedal while depressing the brake pedal. (Engine stops.) Use the M.U.T.-III special function to execute "reset (item No.3: C/V initial & learned value)" while holding them in applied position.
4.Set the selector lever to the P range.
5.Turn the ignition switch to the LOCK (OFF) position, and then wait for ten seconds.
6.
caution Do not start the engine.
Turn the ignition switch to the ON position, and then wait for ten seconds.

7.Check that "P" is displayed on the selector lever position indicator on the multi-information display.
note "P" will disappear while the data is being read. "P" will appear when the data reading is complete.
8.Turn the ignition switch to the LOCK (OFF) position and then to the ON position. Then use the M.U.T.-III to erase the CVT fluid degradation level.