SOLENOID VALVE CHECK



1.While pressing A in the figure, turn B anti-clockwise to unlock the CVT assembly connector, and disconnect the connector.
2.Measure the resistance between the terminals of the applicable solenoid valves and the earth.
Standard value:
Terminal No.
Applicable solenoid valve
Resistance value Ω
1
Line pressure solenoid valve

  • Approximately 5.3 (Fluid temperature: 20°C)
  • Approximately 5.9 (Fluid temperature: 50°C)
  • Approximately 6.5 (Fluid temperature: 80°C)

2
Primary pressure solenoid valve
6
Low brake solenoid valve
7
High clutch and reverse brake solenoid valve
8
Lockup solenoid valve

  • Approximately 6.1 (Fluid temperature: 20°C)
  • Approximately 6.8 (Fluid temperature: 50°C)
  • Approximately 7.5 (Fluid temperature: 80°C)

3.
caution Each solenoid valve cannot be removed or replaced as a single unit.
When the resistance is outside the standard value, replace the CVT assembly.