G AND YAW RATE SENSOR CALIBRATION


caution Before performing calibration, check that the G and yaw rate sensor-related diagnosis code is not set.
caution After the next operation has been completed, carry out the calibration to make ASC-ECU learn the neutral position of the G and yaw rate sensor.

  • ASC-ECU replacement
1.Park the vehicle on a level surface.
2.Turn the ignition switch to the "ON" position.
3.Turn the ignition switch to the "LOCK" (OFF) position.
4.
caution Before connecting or disconnecting M.U.T.-III, always turn the ignition switch to the "LOCK" (OFF) position.
Before setting M.U.T.-III, turn the ignition key to the "LOCK" (OFF) position.
5.Turn the ignition switch to the "ON" position.
6.Select "ABS/ASC/ASTC/WSS."
7.Select "Special function."
8.Select "Sensor calibration."
9.Select "G sensor calibration."
10.Before removing M.U.T.-III from the vehicle, turn the ignition key to the "LOCK" (OFF) position.