INSPECTION PROCEDURE 2: Door(s) cannot be locked or unlocked by central door locking system.




COMMENTS ON TROUBLE SYMPTOM


No operation of the door lock actuator is suspected.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Confirmation of the defective door lock actuator.


Q. Which doors is not locked normally?

Front left door : Go to Step 2.

Front right door : Go to Step 4.

Rear left door : Go to Step 6.

Rear right door : Go to Step 8.

STEP 2. Front door lock actuator (LH) check


Check that the front door lock actuator (LH) works normally. Refer to Door Latch Assembly Inspection .

Q. Is the check result normal?

Go to Step 3.

Replace the front door lock actuator (LH).

STEP 3. Check of short to power supply, short to earth, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and front door lock actuator (LH) connector


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).

Repair the wiring harness.

STEP 4. Front door lock actuator (RH) check


Check that the front door lock actuator (RH) works normally. Refer to Door Latch Assembly Inspection .

Q. Is the check result normal?

Go to Step 5.

Replace the front door lock actuator (RH).

STEP 5. Check of short to power supply, short to earth, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the front door lock actuator (RH) connector


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).

Repair the wiring harness.

STEP 6. Rear door lock actuator (LH) check


Check that the rear door lock actuator works normally. Refer to Door Latch Assembly Inspection .

Q. Is the check result normal?

Go to Step 7.

Replace the rear door lock actuator (LH).

STEP 7. Check of short to power supply, short to earth, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the rear door lock actuator (LH) connector


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).

Repair the wiring harness.

STEP 8. Rear door lock actuator (RH) check


Check that the rear door lock actuator (RH) is in good condition. Refer to Door Latch Assembly Inspection .

Q. Is the check result normal?

Go to Step 9.

Replace the rear door lock actuator (RH).

STEP 9. Check of short to power supply, short to earth, and open circuit in RR-L, RL-U line between the ETACS-ECU connector and the rear door lock actuator (RH) connector


Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunction ).

Repair the wiring harness.