Malfunction of the ignition switch power supply system



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.

COMMENTS ON TROUBLE SYMPTOM


When the power supply system of ignition switch has a problem, none of the equipment and system connected to the ignition switch works even if the ignition switch is operated.

POSSIBLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Voltage measurement at ignition switch connector


(1)Disconnect the ignition switch connector and measure the voltage at ignition switch connector harness side.
(2)Check the voltage between the ignition switch connector (power supply terminal) and body earth.
OK: System voltage

Q. Is the check result normal?

Go to Step 4.

Go to Step 2.

STEP 2. Check the fuse.


Q. Is the check result normal?

Go to Step 3..

Replace the fuse. (Check that there is not a short to earth in the circuit of lower reaches before replacing. If there are any problems, replace the fuse after the circuit of lower reaches is repaired.)

STEP 3. Check of open circuit in power supply line between ignition switch connector and junction block connector


Q. Is the check result normal?

Go to Step 5.

Repair the connector(s) or wiring harness.

STEP 4. Check the ignition switch.


Refer to .

Q. Is the ignition switch in good condition?

Go to Step 5.

Replace the ignition switch.

STEP 5. Retest the system.


Q. Do the device and the system work normally when the ignition switch is operated?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.