diagnosis code 43: SRS warning lamp circuit open-circuited (Lamp does not Switch Off.)





OPERATION
DIAGNOSIS CODE SET CONDITIONS
TROUBLESHOOTING HINTS

DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III actuator test.


Use M.U.T.-III to perform the combination meter actuator tests (Refer to GROUP 54A - Combination meter, actuator test reference table ).

  • Item No.A3: Illuminate the indicator lamp and the warning lamp.
  • Item No.A4: Extinguish the indicator lamps and the warning lamps.

Q. Does the warning lamp illuminate/extinguish?

Go to Step 2.
Replace the combination meter (Refer to GROUP 54A, Combination Meters Assembly ).

STEP 2. Check the harness for open circuit to earth between SRS-ECU connector C-147 (terminal No.18) and combination meter connector C-02 (terminal No.33).




Q. Is the check result normal?

Go to Step 3.

Repair the harness wire between SRS-ECU connector C-147 (terminal No.18) and combination meter connector C-02 (terminal No.33).

STEP 3. Check whether the diagnosis code is reset.


Q. Is diagnosis code 43 set?

Replace the SRS-ECU (Refer to ).
An intermittent malfunction is suspected (Refer to GROUP 00, How to Use Troubleshooting/Inspection Service Points ).