CHECK AT ECU TERMINAL



ETACS-ECU




note Terminal numbers 1 to 20 can not be measured as the ETACS-ECU is mounted on the junction block directly. The values are for reference only.
Terminal No.
Check item
Check condition
Normal condition
1
Output to the power window relay
When the power windows are operative
System voltage
2
Power supply to the central door locking system (battery positive voltage)
Always
System voltage
3
Earth (for ECU)
Always
0 V
4
Ignition switch (ACC)
Ignition switch: ACC
System voltage
5
Output to room lamp
When the room lamp is on
2 V or less
6
Power supply to interior lamp (battery positive voltage)
Always (when the interior lamp off function is off)
System voltage
7
Input from all the door switches
One of the door switches: ON (door open)
0 V
8
Power supply from ignition switch (IG1)
Ignition switch: ON
System voltage
9
Output to right turn-signal lamps
When right turn-signal lamps are on
System voltage
10
Input from driver’s door switch
Driver’s door switch: ON (door open)
0 V
11
Power supply to hazard warning lamp (battery positive voltage)
Always
System voltage
12
Output to central door locking (for locking the doors)
When the door lock actuators lock the doors
System voltage
13
Output to central door locking (for unlocking the doors other than the driver’s door)
When the door lock actuators unlock the doors
System voltage
14
Output to left turn-signal lamps
When the left turn-signal lamps are on
System voltage
15
-
-
-
16
Output to rear wiper
When rear wiper is operating
System voltage
17
Input of rear wiper automatic stop signal
When rear wiper is operating
System voltage
18
Power supply from ignition switch (ACC)
Ignition switch: ACC
System voltage
19
-
-
-
20
Battery power supply (for ECU)
Always
System voltage
21
Input from hood switch
Hood switch ON (hood open)
0 V
22
Output to central door locking (for unlocking the driver’s door)
When the door lock actuators unlock the doors
System voltage
23
Rear washer output
When rear washer is operating
System voltage
24
Input from remote controlled mirror switch (fold switch)
Remote controlled mirror switch (fold switch): ON
0 V
25
-
-
-
26
Photo sensor (auto lamp) power supply
Ignition switch: ON
5 V
27
Photo sensor (auto lamp) input
Ignition switch: ON
Sensor probe illumination intensity: Dark to Bright
0 to approximately 4 V
28
Photo sensor (auto lamp) earth
Always
0 V
29
-
-
-
30
Input to key reminder switch
Key reminder switch: ON (ignition key removed)
0 V
31
Output to electric retractable remote controlled mirror (unfold)
When the door mirrors are folding

System voltage
32
-
-
-
33
Central door lock switch input
Central door lock switch: Locked
0 V
34
Input from central door unlock switch
Central door unlock switch: Unlocked
0 V
35
Input to driver’s door lock actuator (lock switch)
Driver’s door lock: Locked
0 V
36
Input to driver’s door lock actuator (unlock switch)
Driver’s door lock: Unlocked
0 V
37~39
-
-
-
40
Output to electric retractable remote controlled mirror (unfold)
When the door mirrors are unfolding

System voltage
41~43
-
-
-
44
Output to horn
When alarm is triggered (horn is sounding)
0 V
51
Setting diagnosis code or sending input check signal
When diagnosis code is set (the M.U.T.-III is connected or the diagnosis connector No.1 is earthed)
0 to 12 V (pulse signal)
When input check signal is sent
0 V, 12 V (input signal is fluctuating)
52
Input from luggage room lamp switch
Luggage room lamp switch: ON
0 V
53
Input from interior lamp off switch
Interior lamp switch: OFF
0 V
54
Input from front fog lamp switch
Front fog lamp switch: ON
0 V
55
Input from hazard warning lamp switch
Hazard warning lamp switch: ON
0 V
56
Earth (for sensor)
Always
0 V
57, 58
-
-
-
59
SWS communication line
Always
0 to 12 V (pulse signal)
60, 61
-
-
-
62
Input to tailgate lock release handle
Tailgate lock release handle: ON
0 V
63
Input from interior lamp on switch
Interior lamp switch: ON
0 V
64, 65
-
-
-
66
Input from windshield intermittent wiper volume
Turn the ignition switch to the ACC position, and move the wiper volume from "Fast" to "Slow."
0 to 2.5 V
67
Input from diagnosis control
When M.U.T.-III is connected
0 V
68
Input of SWS request signal
Always
0 to 12 V (pulse signal)
69
Output to ignition key cylinder illumination lamp
When ignition key cylinder illumination is on
2 V or less
70
-
-
-
71
Power supply to interior lamp
Always (when the interior lamp off function is off)
System voltage
72, 73
-
-
-
74
Output to security indicator lamp
When security indicator lamp is on
2 V or less

Column switch




Terminal No.
Check item
Check condition
Normal condition
1
System voltage
Always
System voltage
2
Input of SWS request signal
Always
0 to 12 V (pulse signal)
3
SWS communication line
Always
0 to 12 V (pulse signal)
4
Earth
Always
0 V
5
-
-
-
6
Output to windshield intermittent wiper volume
Ignition switch: ACC
Move the wiper volume from "Fast" to "Slow."
0 to 2.5 V
7
-
-
-
8
Back-up output to windshield wiper switch
Windshield low-speed wiper switch or windshield high-speed wiper switch: ON
0 V
9
Power supply from ignition switch (IG1)
Ignition switch: ON
System voltage
10
Back-up output to headlamp switch
Headlamp switch: ON
0 V

Front-ECU




note Measurement is not possible as the front-ECU is mounted on the relay box directly. The values are for reference only.
Terminal No.
Check item
Check condition
Normal condition
1
Output to front fog lamps
When front fog lamps are on
System voltage
2
Output to high-beam headlamps
When high-beam headlamps are on
System voltage
3, 4
Battery power supply (for headlamps)
Always
System voltage
5
Battery power supply (for tail lights)
Always
Battery voltage
6
Output to low-beam headlamps
When low-beam headlamps are on
Battery voltage
7
Battery power supply (for ECU)
Always
System voltage
8
Output to tail lamps
When the tail lamps are on
System voltage
9~11
-
-
-
21
Output to windshield washer
When windshield washer is operating
System voltage
22
SWS communication line
Always
0 to 12 V (pulse signal)
23
Input of windshield wiper automatic stop signal
When windshield wipers are operating
System voltage
24
Power supply from ignition switch (ACC)
Ignition switch: ACC
System voltage
25
Back-up input from headlamp switch
Headlamp switch: ON
0 V
26
Back-up input from windshield wiper switch
Windshield low-speed wiper switch or windshield high-speed wiper switch: ON
0 V
27
Output to windshield wiper (low speed operation)
When windshield wipers are operating at low speed
System voltage
28
Output to windshield wiper (high speed operation)
When windshield wipers are operating at high speed
System voltage
29
-
-
-
30
Power supply to the ignition switch (IG2)
Ignition switch: ON
System voltage
31
Earth
Always
0 V

Power window main switch




Terminal No.
Check item
Check condition
Normal condition
1
Output to power window motor
-
-
2
Earth
Always
0 V
3
-
-
-
4
SWS communication line (to ETACS-ECU)
Always
0 to 12 V (pulse signal)
5
-
-
-
6
Power supply
Power window relay: ON
System voltage
7
Output to power window motor
-
-
8
Input from power window motor (pulse sensor earth)
-
0 V
9
Input from power window motor (pulse sensor signal)
When the power windows are operating
0 to 5 V (pulse signal)
10
Input from power window motor (pulse sensor signal)
When the power windows are operating
0 to 5 V (pulse signal)
11
SWS communication line (power window sub switch)
Power window relay: ON
0 to 12 V (pulse signal)
12
Input from power window motor (power supply to pulse sensor)
When the power windows are operating
5 V
13, 14
-
-
-

Power window sub switch




Terminal No.
Check item
Check condition
Normal condition
1
Earth
Always
0 V
2
Input from power window motor
-
-
3
Input from power window motor
-
-
4
Power supply
Power window relay: ON
System voltage
5
Output to power window motor
-
-
6
SWS communication line
Power window relay: ON
0 to 12 V (pulse signal)
7
Output to power window motor
-
-
8
Input from power window motor
-
-

Sunroof motor assembly




Terminal No.
Check item
Check condition
Normal condition
1
System voltage (for motor)
Always
System voltage
2
Power supply from ignition switch (IG2)
Ignition switch: ON
System voltage
3, 4
-
-
-
5
Earth
Always
0 V
6
Input from sunroof switch (close)
Sunroof switch: Close
0 V
7
-
-
-
8
Input from sunroof switch (open)
Sunroof switch: Open
0 V
9
-
-
-
10
SWS communication line (to ETACS-ECU)
Always
0 to 12 V (pulse signal)