INSPECTION PROCEDURE P-11: The hazard warning lamp switch signal is not received.



caution Whenever the ECU is replaced, ensure that the input signal circuit is normal.




COMMENTS ON TROUBLE SYMPTOM


Input signal from the hazard warning lamp switch is used to operate the functions below. If the signal is abnormal, these functions will not work normally.

  • Turn-signal lamp operation sound
  • Keyless entry system (encrypted code registration)
  • Keyless entry hazard answerback
  • Hazard warning lamp

POSSIBLE CAUSES



  • Malfunction of the hazard warning lamp switch
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


Step 1. Connector check: C-123 hazard warning lamp switch connector



Q. Is the check result normal?

Go to Step 2.

Repair the defective connector.

Step 2. Check the hazard warning lamp switch.


Refer to GROUP 54A - Hazard warning lamp switch .

Q. Is the check result normal?

Go to Step 3.
Replace the hazard warning lamp switch.

Step 3. Resistance measurement at the C-123 hazard warning lamp switch connector.



(1)Disconnect the connector, and measure at the wiring harness side.

(2)Resistance between C-123 hazard warning lamp switch connector terminal No.2 and body earth
OK: 2 Ω or less

Q. Is the check result normal?

Go to Step 5.

Go to Step 4.

Step 4. Check the wiring harness between C-123 hazard warning lamp switch connector terminal No.2 to the body earth.




  • Check the earth wires for open circuit.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).

Repair the wiring harness.

Step 5. Connector check: C-221 ETACS-ECU connector



Q. Is the check result normal?

Go to Step 6.

Repair the defective connector.

Step 6. Check the wiring harness between C-221 ETACS-ECU connector terminal No.55 to C-123 hazard warning lamp switch connector terminal No.1.





  • Check the input line for open circuit.

Q. Is the check result normal?

Go to Step 7.

Repair the wiring harness.

Step 7. ETACS switch data by using the SWS monitor


Check the input signal from the hazard warning lamp switch.

  • hazard warning lamp switch: from OFF to ON
Item No.
Item name
Normal condition
Item 04
HAZARD LMP SW
OFF to ON (only when switch is operated)
OK: Normal condition is displayed.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.