INSPECTION PROCEDURE B-5: Turn-signal lamp operation sound function does not work normally.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.




COMMENTS ON TROUBLE SYMPTOM


The ETACS-ECU operates this function in accordance with the input signals below.

  • Turn-signal lamp switch
  • Hazard warning lamp switch
If this function does not work normally, these input signal circuit(s) or the ETACS-ECU may be defective. Note that this function can be disabled/enabled by the customize function (default setting; disabled). In order to change the setting, the SWS monitor is required.

POSSIBLE CAUSES



  • Malfunction of the column switch
  • Malfunction of the ETACS-ECU
  • Damaged harness wires and connectors

DIAGNOSTIC PROCEDURE


Step 1. Check that the turn-signal lamps operate.


When the turn-signal lamp switch or the hazard warning lamp switch is operated, check that the turn-signal lamps flash.

Q. Is the check result normal?

Go to Step 2.
First, repair the turn-signal lamp(s) (Refer to Trouble Symptom Chart ).

Step 2. Customize function by using the SWS monitor


Use the SWS monitor customisation function to confirm that "T/SIG.BUZZER" is set to "W.FUNCTION".

Q. Is the check result normal?

Go to Step 3.
Use the SWS monitor customisation function to set "T/SIG.BUZZER" to "W.FUNCTION" (Refer to ).

Step 3. ECU check by using the SWS monitor


Check that the power supply and earth lines to the ETACS-ECU and the column switch (column-ECU) and the SWS communication lines are normal.

  • Ignition switch: ON
ECUS TO BE CHECKED
  • ETACS-ECU
  • Column ECU
OK: "OK" are displayed for all the items

Q. Are the check result normal?

Normal conditions are displayed for all the items. : Go to Step 4.
"NG" is displayed on the "ETACS ECU" menu. : Refer to Inspection Procedure A-3 "Communication with the ETACS-ECU is not possible ."
"NG" is displayed on the "COLUMN ECU" menu. : Refer to Inspection Procedure A-2 "Communication with the column switch (column-ECU) is not possible ."

Step 4. SWS monitor data list


Check the SWS communication input signal, which are related to the turn-signal lamp operation sound function.
<Selected item> ETACS-ECU
  • Hazard warning switch: ON
Item No.
Item name
Normal condition
Item 43
BUZZER
ON
OK: Normal condition is displayed.

Q. Is the check result normal?

Go to Step 5.
Replace the ETACS-ECU.

Step 5. Retest the system.


Check that the turn-signal lamp operation sound function works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).
Replace the ETACS-ECU.