INSPECTION PROCEDURE N-3: The front fog lamp indicator does not illuminate normally.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.




COMMENTS ON TROUBLE SYMPTOM


If the front fog lamp indicator does not illuminate normally, connector(s), wiring harness in the CAN bus lines, the ETACS-ECU or the combination meter may be defective.

POSSIBLE CAUSES



  • The combination meter may be defective
  • The ETACS-ECU may be defective
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


Step 1. Check the front fog lamps.


When the front fog lamp switch is operated, check that the front fog lamps illuminate/go off normally.

Q. Is the check result normal?

Go to Step 2.
Refer to Inspection Procedure N-2 "Any of the front fog lamps does not illuminate ."

Step 2. M.U.T.-III CAN bus diagnostics.


Use the M.U.T.-III to diagnose the CAN bus lines.

Q. Is the check result normal?

Go to Step 3.
Repair the CAN bus line (Refer to GROUP 54F, Diagnosis ).

Step 3. Check for combination meter diagnosis code.


Check whether the combination meter-related diagnosis code is set.

Q. Is the diagnosis code set?

Diagnose the combination meter (Refer to GROUP 54A - Troubleshooting ).
Go to Step 4.

Step 4. M.U.T.-III actuator test


Perform the actuator test for the combination meter, and check that the front fog lamp indicator illuminates (Refer to GROUP 54A - Combination Meter ).

Q. Is the check result normal?

Replace the ETACS-ECU.
Replace the combination meter.