ACTUATOR TEST TABLE



Item No.
Check items
Drive content
01
Front blower fan: OFF
Stop
02
Front blower fan: Middle
Middle speed
03
Front blower fan: High
High speed
04
Rear blower fan: OFF <Vehicles with rear heater, rear cooler or dual automatic A/C>
Stop
05
Rear blower fan: AUTO <Vehicles with rear heater, rear cooler or dual automatic A/C>
AUTO
06
Rear blower fan: Lo <Vehicles with rear heater, rear cooler or dual automatic A/C>
Low speed
07
Rear blower fan: Middle <Vehicles with rear heater, rear cooler or dual automatic A/C>
Middle speed
08
Rear blower fan: High <Vehicles with rear heater, rear cooler or dual automatic A/C>
High speed
09
Condenser fan: OFF
Stop
0A
Condenser fan: 50%
Middle speed
0B
Condenser fan: 100%
High speed
10
F.Air mix dumper motor: 0%
Opening angle: Approximately 0% (MAX COOL)
11
F.Air mix dumper motor: 50%
Opening angle: Approximately 50%
12
F.Air mix dumper motor: 100%
Open angle: Approximately 100% (MAX COOL)
13
R.Air mix dumper motor: 0% <Vehicles with rear heater, rear cooler or dual automatic A/C>
Opening angle: Approximately 0% (MAX COOL)
14
R.Air mix dumper motor: 50% <Vehicles with rear heater, rear cooler or dual automatic A/C>
Opening angle: Approximately 50%
15
R.Air mix dumper motor: 100% <Vehicles with rear heater, rear cooler or dual automatic A/C>
Open angle: Approximately 100% (MAX COOL)
20
Air outlet c/o dumper: FACE
Air outlet at FACE position
21
Air outlet c/o dumper: Bi-Level
Air outlet at FACE/FOOT position
22
Air outlet c/o dumper: FOOT
Air outlet at FOOT position
23
Air outlet c/o dumper: DEF/FOOT
Air outlet at DEF/FOOT position
24
Air outlet c/o dumper: DEF
Air outlet at DEF position
30
In/out changeover dumper: Recirc
Moved to recirculation-side
31
In/out changeover dumper: Fresh
Moved to outside air-side
40
Rear defogger switch: OFF
Rear window defogger OFF
41
Rear defogger switch: ON
Rear window defogger ON
42
PTC heater relay: OFF <Vehicles with rear heater or dual automatic A/C>
PTC heater OFF
43
PTC heater relay: ON <Vehicles with rear heater or dual automatic A/C>
PTC heater ON (air outlet at FACE or DEF position, not operate with blower OFF)
50
Idle up request: OFF
Idle rpm (not operate with compressor ON)
51
Idle up request: low load
Idle up with low load rpm
52
Idle up request: high lode
Idle up with high load rpm