INITIALISATION PROCEDURE FOR LEARNING VALUE IN MPI ENGINE



Initialise learning values in the MPI engine when one of the following service operations is performed.

note *: Initialise CVT related learning value.

INITIALISATION PROCEDURE





caution To prevent damage to M.U.T.-III, always turn the ignition switch to the LOCK (OFF) position before connecting or disconnecting M.U.T.-III.
1.After the ignition switch is in LOCK (OFF) position, connect the M.U.T.-III to the diagnosis connector.
2.Turn the ignition switch to the ON position.
3.Select "MPI/GDI/DIESEL" from System select Screen of the M.U.T.-III.
4.Select "Special Function" from MPI/GDI/DIESEL Screen.
5.Select "Learned value reset" from Special Function Screen.
6.Select "All learned value" from Learned value reset Screen
7.Initialise the learning value by pressing the OK button.
8.After initialising the learning value, the learning value of MPI engine idling is necessary. Learning procedure for idling in MPI engine (Refer to ).