SERVICE SPECIFICATIONS



Item
Standard value
CVT fluid temperature sensor resistance kΩ
At 20°C
Approximately 6.5
At 50°C
Approximately 2.2
At 80°C
Approximately 0.9
Line pressure solenoid valve coil resistance Ω
Fluid temperature: 20°C
Approximately 5.3
Fluid temperature: 50°C
Approximately 5.9
Fluid temperature: 80°C
Approximately 6.5
Primary pressure solenoid valve coil resistance Ω
Fluid temperature: 20°C
Approximately 5.3
Fluid temperature: 50°C
Approximately 5.9
Fluid temperature: 80°C
Approximately 6.5
Low brake solenoid valve coil resistance Ω
Fluid temperature: 20°C
Approximately 5.3
Fluid temperature: 50°C
Approximately 5.9
Fluid temperature: 80°C
Approximately 6.5
High clutch and reverse brake solenoid valve coil resistance Ω
Fluid temperature: 20°C
Approximately 5.3
Fluid temperature: 50°C
Approximately 5.9
Fluid temperature: 80°C
Approximately 6.5
Lockup solenoid valve coil resistance Ω
Fluid temperature: 20°C
Approximately 6.1
Fluid temperature: 50°C
Approximately 6.8
Fluid temperature: 80°C
Approximately 7.5
Engine stall speed r/min
D range
Approximately 2,300
R range
Approximately 2,300
Shift lock solenoid resistance Ω
40 ± 2