INSPECTION



POWER WINDOW MAIN SWITCH CONTINUITY CHECK <Vehicles with safety system>





<DRIVER’S SWITCH>
Switch position
Tester connection
Specified condition
UP
7* - 14
Continuity exists (2 Ω or less)
OFF
7* - 14, 7* - 15
DOWN
7* - 15
Switch position
Battery connection
Tester connection
Specified condition
UP

  • Connect terminal No. 7* to the negative battery terminal.
  • Connect terminal No. 10 and No. 16 to the positive battery terminal.

7* - 15
Battery voltage
DOWN
7* - 14
note *: Set the window lock switch to UNLOCK position.

<FRONT PASSENGER’S SWITCH>
Switch position
Tester connection
Specified condition
UP
7* - 11, 10 - 12
Continuity exists (2 Ω or less)
OFF
7* - 11, 7* - 12
DOWN
7* - 12, 10- 11
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S LEFT SWITCH>
Switch position
Tester connection
Specified condition
UP
1 -7*, 2 - 10
Continuity exists (2 Ω or less)
OFF
1 -7*, 2 -7*
DOWN
1 - 10, 2 -7*
note *: Set the window lock switch to UNLOCK position.

<REAR PASSENGER’S RIGHT SWITCH>
Switch position
Tester connection
Specified condition
UP
7* - 8, 9 - 10
Continuity exists (2 Ω or less)
OFF
7* - 8, 7* - 9
DOWN
7* - 9, 8 - 10
note *: Set the window lock switch to UNLOCK position.