GENERAL INFORMATION



OUTLINE OF CHANGE


As the battery model has been changed and the battery current sensor is employed, the service procedure has been changed as follows. The other service procedures are the same as before.

GENERAL SPECIFICATIONS


Item
Specifications
New
Old
Type
80D23L (CA)
34B19L (S)
Voltage V
12
12
Capacity (5-hour rate) Ah
59
29
Electrolytic fluid specific gravity (fully charged state at 20°C)
1.280
1.280