Inspection Procedure 2: The USB data cannot be replayed.



caution Before replacing the hands free-ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal. Check that the USB memory device or iPod® is also normal.

COMMENTS ON TROUBLE SYMPTOM


If the sound replay is impossible with the USB mode, the USB cable, hands free-ECU, or radio and CD player may be defective, or a communication error between the radio and CD player and hands free-ECU may have occurred.
note Before troubleshooting, check that the music file (the customer tried to replay) can be replayed.

PROBABLE CAUSES



  • The radio and CD player may be defective.
  • The hands free-ECU may be defective.
  • The USB cable may be defective.
  • Damaged harness wires and connectors

DIAGNOSIS PROCEDURE


STEP 1. Check the radio and CD player operation.


Check if the radio and CD player normally and the sound is output.

Q. Is the check result normal?

Go to Step 2.
Troubleshoot the radio and CD player.

STEP 2. Check the diagnosis mode


Check if the hands free-ECU can be switched to the diagnosis mode (Refer to ).

Q. Is the check result normal?

Go to Step 3.
Perform Inspection Procedure 5 DIAGNOSIS MODE cannot be made an entry (Refer to ).

STEP 3. Check the USB cable.


Check that the USB cable is connected to the hands free-ECU normally. Or check the USB cable for damage such as bend.

Q. Is the check result normal?

Go to Step 4.
Replace or repair the USB cable.

STEP 4. Check of short to power supply, short to earth, and open circuit in NAVL, NAVR line between hands free-ECU connector and radio and CD player connector.


Q. Is the check result normal?

Go to Step 5.
Repair the connector(s) or wiring harness.

STEP 5. Replace the hands free-ECU temporarily, and check the trouble symptom.


Replace the hands free-ECU temporarily, and check that the sound is output from the speaker.

Q. Is the check result normal?

Replace the hands free-ECU.
Replace the radio and CD player.