DAMPER CONTROL MOTOR ASSEMBLY INSPECTION



CHECK THE MODE SELECTION DAMPER CONTROL MOTOR AND POTENTIOMETER


caution Stop energising when the lever is set to the operation stopping position.


1.

MOTOR CHECK
Battery connection (+) terminal
Battery connection
(-) terminal
Lever operation
1
2
Rotate to the FACE <LHD>, DEF <RHD> side
2
1
Rotate to the DEF <LHD>, FACE <RHD> side
2.Potentiometer check
    When the resistance value between connector terminals 3 and 4 <LHD>, 2 and 6 <RHD> is measured while checking the motor, check that the resistance value changes gradually within the standard value.
Standard value: 1.20 (FACE) - 4.80 (DEF) kΩ <LHD>
Standard value: 1.98 (FACE) - 4.80 (DEF) kΩ <RHD>

CHECK THE AIR MIXING DAMPER CONTROL MOTOR AND POTENTIOMETER


caution Stop energising when the lever is set to the operation stopping position.


1.

MOTOR CHECK
Battery connection (+) terminal
Battery connection
(-) terminal
Lever operation
2
1
Rotate to the COOL side. <LHD>
Rotate to the HOT side. <RHD>
1
2
Rotate to the HOT side. <LHD>
Rotate to the COOL side. <RHD>
2.Potentiometer check
    When the resistance value between connector terminals 3 and 4 <LHD>, 2 and 6 <RHD> is measured while checking the motor, check that the resistance value changes gradually within the standard value.
Standard value: 1.38 (MAX COOL) - 4.80 (MAX HOT) kΩ <LHD>
Standard value: 1.20 (MAX COOL) - 4.80 (MAX HOT) kΩ <RHD>

CHECK THE OUTSIDE/INSIDE AIR SELECTION DAMPER CONTROL MOTOR


caution Stop energising when the lever is set to the operation stopping position.



MOTOR CHECK
Battery connection (+) terminal
Battery connection
(-) terminal
Lever operation
1 <LHD>
7 <RHD>
3 <LHD>
5 <RHD>
Rotate to the inside. <LHD>
Rotate to the outside. <RHD>
1 <LHD>
5 <RHD>
4 <LHD>
7 <RHD>
Rotate to the outside. <LHD>
Rotate to the inside. <RHD>