Code No. P0421: Warm Up Catalyst Malfunction (right bank) <Except Euro 2>




FUNCTION




TROUBLE JUDGEMENT


Check Conditions
Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Check for leakage of exhaust emission from exhaust manifold.


Q. Is the check result normal?

Go to Step 2.
Repair.

STEP 2. M.U.T.-III data list



  • Data list reference table (Refer to ).

    1. Item AC: Right bank oxygen sensor (front)
    2. Item AD: Right bank oxygen sensor (rear)

Q. Are the check results normal?

Go to Step 3.
Perform the diagnosis code classified check procedure for the sensor that has shown an abnormal data value. Inspection chart for diagnosis code (Refer to ).

STEP 3. M.U.T.-III data list



  • Item AC: Right bank oxygen sensor (front)
OK: 0 - 0.4 and 0.6 - 1.0 volt should alternate 15 times or more within 10 seconds (engine speed at 2,000 r/min).

Q. Is the check result normal?

Go to Step 4.
Replace the right bank oxygen sensor (front).

STEP 4. Replace the right bank oxygen sensor (rear)



  • After replacing the right bank oxygen sensor (rear), reconfirm whether the diagnosis code is stored.

Q. Is diagnosis code stored?

Go to Step 5.
Check end.

STEP 5. Replace the catalytic converter (right bank)



  • After replacing the catalytic converter (right bank), reconfirm whether the diagnosis code is stored.

Q. Is diagnosis code stored?

Replace the engine-ECU.
Check end.