Code No. P0151: Left Bank Oxygen Sensor (front) Circuit Low Voltage




OPERATION




FUNCTION




TROUBLE JUDGEMENT


Check Conditions
Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III data list



  • Data list reference table (Refer to ).

    1. Item AE: Left bank oxygen sensor (front)

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Go to Step 2.

STEP 2. Voltage measurement at left bank oxygen sensor (front) connector (OFLE line).


(1)Disconnect the connector, and measure at the wiring harness side.
(2)Ignition switch: ON
(3)Check the voltage between the left bank oxygen sensor (front) connector (OFLE line) and body earth.
OK: 0.4 - 0.6 V

Q. Is the check result normal?

Go to Step 5.
Go to Step 3.

STEP 3. Check of short to earth and open circuit in OFLE line between left bank oxygen sensor (front) connector and engine-ECU connector.


Q. Is the check result normal?

Go to Step 4.
Repair the connector(s) or wiring harness.

STEP 4. M.U.T.-III data list



  • Data list reference table (Refer to ).

    1. Item AE: Left bank oxygen sensor (front)

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Replace the engine-ECU.

STEP 5. Check of damage in OFLE line between left bank oxygen sensor (front) connector and engine-ECU connector.


Q. Is the check result normal?

Go to Step 6.
Repair the connector(s) or wiring harness.

STEP 6. Voltage measurement at left bank oxygen sensor (front) connector (O2FL line).


(1)Use special tool test harness (MD998464) to connect connector, and measure at pick-up harness.
(2)Engine: After warm-up
(3)Transmission: P range
(4)Check the voltage between the left bank oxygen sensor (front) connector (O2FL line) and body earth.
OK:
    When the engine is 2,500 r/min, the output voltage should repeat 0.9 V or less <=> 1.1 to 1.5 V alternately.

Q. Is the check result normal?

Go to Step 8.
Go to Step 7.

STEP 7. Check left bank oxygen sensor (front) itself.



  • Left bank oxygen sensor (front) check (Refer to ).

Q. Is the check result normal?


    Repair or replace the connector(s), or check and repair the harness of short circuit to earth in O2FL line between left bank oxygen sensor (front) connector and engine-ECU connector.
Replace the left bank oxygen sensor (front).

STEP 8. Check of open circuit and damage in O2FL line between left bank oxygen sensor (front) connector and engine-ECU connector.


Q. Is the check result normal?

Go to Step 4.
Repair the connector(s) or wiring harness.