DIAGNOSIS PROCEDURE |
STEP 1. Check of short to power supply in EGC line between suction control valve connector and engine-ECU connector. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the connector(s) or wiring harness. |
|
STEP 2. M.U.T.-III diagnosis code |
|
Q.
Is the diagnosis code set?
|
Replace the engine-ECU. |
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions). |
|