Code No. P0381: Glow Plug Open/Short Malfunction




OPERATION




FUNCTION




TROUBLE JUDGEMENT


Check Conditions
Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




PROBABLE CAUSES




DIAGNOSTIC PROCEDURE


STEP 1. Check of open circuit, short to earth, and damage in power supply line between glow control unit connector and No.1 glow plug connector.


Q. Is the check result normal?

Go to Step 2.
Repair the connector(s) or wiring harness.

STEP 2. Check of open circuit, short to earth, and damage in power supply line between glow control unit connector and No.2 glow plug connector.


Q. Is the check result normal?

Go to Step 3.
Repair the connector(s) or wiring harness.

STEP 3. Check of open circuit, short to earth, and damage in power supply line between glow control unit connector and No.3 glow plug connector.


Q. Is the check result normal?

Go to Step 4.
Repair the connector(s) or wiring harness.

STEP 4. Check of open circuit, short to earth, and damage in power supply line between glow control unit connector and No.4 glow plug connector.


Q. Is the check result normal?

Go to Step 5.
Repair the connector(s) or wiring harness.

STEP 5. Replace the glow control unit.



  • After replacing the glow control unit, reconfirm whether the diagnosis code is stored.

Q. Is the diagnosis code stored?

Replace the engine-ECU.
Check is end.