DIAGNOSIS PROCEDURE |
STEP 1. Check of short to power supply in FSL+ line between electronic control coupling solenoid (front) connector and AWC-ECU connector. |
Q.
Is the check result normal?
|
Go to Step 2. |
|
Repair the connector(s) or wiring harness. Then go to Step 8. |
|
STEP 2. Check of short to power supply in FSL- line between electronic control coupling solenoid (front) connector and AWC-ECU connector. |
Q.
Is the check result normal?
|
Go to Step 3. |
|
Repair the connector(s) or wiring harness. Then go to Step 8. |
|
STEP 3. Check of the electronic control coupling solenoid (Front) |
Refer to . |
Q.
Is the check result normal?
|
Go to Step 4. |
|
Replace the transfer assembly (Refer to ). Then
go to Step 8. |
|
STEP 4. Check of short to power supply in SOL+ line between electronic control coupling solenoid (Centre) connector and AWC-ECU connector. |
Q.
Is the check result normal?
|
Go to Step 5. |
|
Repair the connector(s) or wiring harness. Then go to Step 8. |
|
STEP 5. Check of short to power supply in SOL- line between electronic control coupling solenoid (Centre) connector and AWC-ECU connector. |
Q.
Is the check result normal?
|
Go to Step 6. |
|
Repair the connector(s) or wiring harness. Then go to Step 8. |
|
STEP 6. Check of the electronic control coupling solenoid (Centre) |
Refer to GROUP 27C -
On-vehicle Service. |
Q.
Is the check result normal?
|
Go to Step 7. |
|
Replace the electronic control coupling (Centre) (Refer to GROUP 27C -
Electronic
Control Coupling). Then go to Step 8. |
|
STEP 7. Check whether the diagnosis code is set again. |
Q.
Is diagnosis code No.C1626 set?
|
Replace the AWC-ECU. (Refer to ). Then go
to Step 8. |
|
Intermittent malfunction. (Refer to GROUP 00 -
How to Cope with Intermittent
Malfunction). |
|
STEP 8. Check whether the diagnosis code is set again. |
Q.
Is diagnosis code No.C1626 set?
|
Return to Step 1. |
|
This diagnosis is complete. |
|