caution |
|
REMOVAL SERVICE POINT |
<<A>> PROPELLER SHAFT DISCONNECTION |
1.Put mating marks on the
flange yoke and the electronic control
coupling. 2.Hold the disconnected propeller shaft with a wire so that it will not be bent sharply. |
INSTALLATION SERVICE POINT |
>>A<< DIFFERENTIAL CARRIER ASSEMBLY INSTALLATION |
1.Check that the length of
the electronic control coupling stud bolt (A) is within the
standard
value range. Standard value: 21.6 - 24.4 mm 2.If the length exceeds the standard value, replace the stud bolt. Tightening torque: 13 ± 2 N·m
|