1.Move the stabilizer link
ball joint stud back and forth for several times, install
the
stud with nut, and measure the stabilizer link ball joint
rotation torque using the preload socket
(Special tool: MB990326). Standard value: 0.3
to 2.9 N·m 2.When the measured value
exceeds the standard range, replace the stabilizer
link. 3.When the measured value is lower than the
standard value, check the stabilizer link
ball joint that there is no looseness or gritty feeling. If
there is no looseness or gritty
feeling, it is judged as usable.
|