INSPECTION



DOOR MIRROR ASSEMBLY OPERATION CHECK


Remove the door trim, and then connect the battery to the door mirror assembly connector to check that the door mirror operates.

Battery connection
Operation direction

  • Connect terminal 12 to the negative battery terminal.
  • Connect terminal 5 to the positive battery terminal.

Up

  • Connect terminal 12 to the positive battery terminal.
  • Connect terminal 5 to the negative battery terminal.

Down

  • Connect terminal 13 to the negative battery terminal.
  • Connect terminal 12 to the positive battery terminal.

Right

  • Connect terminal 13 to the positive battery terminal.
  • Connect terminal 12 to the negative battery terminal.

Left

REMOTE CONTROLLED MIRROR SWITCH CONTINUITY CHECK



Switch position
Tester connection
Specified condition
Left side
Up
1 - 6, 9 - 11
Continuity
exists(2 Ω or less)
Down
1 - 11, 6 - 9
Right
1 - 6, 9 - 10
Left
1 - 10, 6 - 9
Right side
Up
1 - 6, 3 - 9
Down
1 - 3, 6 - 9
Right
1 - 6, 2 - 9
Left
1 - 2, 6 - 9