Inspection Procedure 4: The image is not switched when the selector lever is moved to the R position.




COMMENT ON TROUBLE SYMPTOM


When the monitor screen is not switched although the selector lever is moved to the "R" position, the selector lever signal system may be defective.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III CAN bus diagnostics


Use the M.U.T.-III to diagnose the CAN bus lines.

Q. Is the check result normal?

Go to Step 2.

Repair the CAN bus line (Refer to GROUP 54C - Troubleshooting).

STEP 2. Check the operation of the back-up lamp.


Check that the back-up lamp illuminate normally.

Q. Is the check result normal?

Go to Step 3.

Troubleshoot the back-up lamp.

STEP 3. M.U.T.-III data list.


Using the camera-ECU service data.

Item No.
M.U.T.-III display
Check condition
Normal condition
1
Shift information
Selector lever: except R position
Not R
Selector lever: R position
R

Q. Is the check result normal?

Go to Step 5.

Go to Step 4.

STEP 4. M.U.T.-III other system diagnosis code


Check whether the ETACS-ECU diagnosis codes are set or not.

Q. Is the diagnosis code set?

Diagnose the ETACS-ECU.

Go to Step 5.

STEP 5. Retest the system.


Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction).

Replace the camera-ECU (Refer to ).