Inspection Procedure 1: The system is not activated when the automatic high beam switch is operated.



caution
  • Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.

COMMENTS ON TROUBLE SYMPTOM


When the operation indicator lamp in the combination meter does not illuminate, the column switch (automatic high beam switch), the ETACS-ECU or the FCM/LDW/AHB-ECU may be defective.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III other system diagnosis code.


Check if the diagnosis code is set in the ETACS-ECU.

Q. Is the diagnosis code set?

Troubleshoot the ETACS-ECU.

Go to Step 2.

STEP 2. Check that the headlamps operate.


Carry out the following check.

Q. Is the check result normal?

Go to Step 3.

Troubleshoot the headlamp.

STEP 3. M.U.T.-III other system data list.


Using the ETACS-ECU data list (Refer to ), check the automatic high beam switch signal.

Item No.
Item name
Normal condition
Item 362
AHB switch
ON

Item No.
Item name
Normal condition
Item 362
AHB switch
OFF
OK: Normal condition is displayed.

Q. Is the check result normal?

Go to Step 4.

NO : Replace the column switch (Refer to ).

STEP 4. Retest the system.


Check that the automatic high beam operates normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction).

Replace the ETACS-ECU.