Diagnosis Item
24: Diagnose when the M.U.T.-III cannot receive the data sent by CAN box unit <vehicles
with MMCS>.
caution |
When servicing a CAN bus line,
earth yourself by touching a metal object such as an unpainted water pipe. If you fail to do,
a component connected to the CAN bus line may be broken.
|
FUNCTION
The diagnostic result demonstrates that "the M.U.T.-III cannot receive the sent data from
the CAN box unit" when the M.U.T.-III checks the periodically sent data from each ECU and cannot
receive the CAN box unit data only.
TROUBLE JUDGEMENT CONDITIONS
M.U.T.-III judges the trouble when the periodically sent data from CAN box unit cannot
be received.
PROBABLE CAUSES
- Damaged harness wires and connectors
- Power supply circuit malfunction of the CAN box unit
- Malfunction of the CAN box unit
|
STEP 1. Connector check: joint connector (CAN5) and CAN
box unit connector
|
|
caution |
The strand end of the twist wire should be within 10 cm from
the connector.
|
|
|
When checking the joint connector, ensure that its wiring harness side and its short pins
are not damaged.
|
|
Q.
Is the check result normal?
|
|
Go to Step 2.
|
|
|
|
Repair the defective connector. Replace the joint connector as necessary.
|
|
|
|
STEP 2. Resistance measurement at joint connector (CAN5) and CAN box
unit connector.
|
|
caution |
A digital multimeter should be used.
|
|
|
caution |
The test wiring harness should be used.
|
|
|
(1)Disconnect joint connector (CAN5) and the CAN box unit connector, and measure at
the wiring harness side.
|
|
(2)Turn the ignition switch to the LOCK (OFF) position.
|
|
(3)
caution |
When measuring the resistance, disconnect the negative battery
terminal.
|
Ensure that the negative battery terminal is disconnected.
|
|
(4)Continuity between joint connector (CAN5) terminal No.3 and CAN box unit connector
terminal No.14 OK: Continuity (2 Ω or less)
|
|
(5)Continuity between joint connector (CAN5) terminal No.14 and CAN box unit connector
terminal No.13 OK: Continuity (2 Ω or less)
caution |
Strictly observe the specified wiring harness repair procedure.
|
|
|
Q.
Is the check result normal?
|
|
<All the resistances measure 2 Ω or less> Power supply
to the CAN box unit may be suspected. Diagnose the CAN box unit. Refer to GROUP 54A CAN box
unit - Troubleshooting .
|
|
|
|
NO : <Either or all of the resistances measure more than 2 Ω> Repair
the wiring harness between joint connector (CAN5) and the CAN box unit connector.
|
|
|