ACTUATOR TEST TABLE



If it is not in this list: Click
 
Item No.
Item name
Test contents
Set value (M.U.T.-III indication)
1
LDW indicator: Standby request
The icon in the combination meter should appear under the warning monitor status (standby mode).
-
2
LDW indicator: Warning request
The icon in the combination meter should appear under the warning status (WARNING L-LANE or WARNING R-LANE).
Warning R-lane
Warning L-lane
3
LDW indicator: TEMP. fail req.
The icon in the combination meter should appear when the LDW precheck function is in progress, or the LDW is defective (excluding too hot FCM/LDW/AHB-ECU and an intermittent malfunction).
-
4
LDW indicator: System fail req.
The icon in the combination meter should appear under the warning monitor status (standby mode).
-

If it is not in this list: Click