LDW SWITCH INSPECTION



ON/OFF CHECK



Switch position
Terminal number
Normal condition
ON (switch pushed)
2 - 5
Continuity exists (2 Ω or less)
OFF (switch released)
No continuity

ILLUMINATION CHECK


Apply the battery voltage to the connector terminal No. 3, earth the terminal No. 4, and then check that the illuminates.