1.Place a calibration
plate. (1)
Fabricate
two calibration plate according to dimensions shown in
illustration. (2)
Place
them as shown. (3)
Place the calibration plate and the vehicle as
shown. Calibration plate
position
- Distance between the sensor on the
FCM/LDW/AHB-ECU
and the calibration plate: 2500 ± 10
mm
(Distance between the centre of the front
axle and the calibration plate: 1737
mm)
- Dimension (height) between the floor and the
centre of
the calibration plate: 1300 ± 10
mm
2.Turn the ignition switch "OFF"
position. 3.Connect the M.U.T.-III to the
diagnosis connector (For how to connect the M.U.T.-III,
refer to GROUP 00 - Diagnosis
function). 4.Turn the ignition switch to the "ON"
position. (Do not start the engine.) 5.Operate the
M.U.T.-III as below: (1)
Select "FCM/LDW/AHB" on the system selection
screen. (2)
Select "Special function". (3)
Select "Learning". (4)
Select "Camera calibration", and then execute the
calibration.
|
note |
The indicator on
the display should illuminate
according to the calibration status
as
shown in the table.
Display
content
|
Calibration
is in
progress
|
Calibration
not
complete
|
Calibration
complete
|
|
Flashing
(2Hz)
|
Flashing
(1Hz)
|
OFF
|
|
Flashing
(2Hz)
|
OFF
|
ON
|
|
Display
|
No
display
|
No
display
|
|
No
display
|
Display
|
No
display
|
|
|
(5)
When you select item No. 48 "Calibration condition" on
"Camera calibration", you can
monitor a calibration result. OK:
Completed NG: Diagnosis code No. C1754
is set together with the diagnosis code, which indicates
why the calibration has
failed.
Explanation of diagnosis
code, and remedy
Diagnosis code No.
|
Contents
|
Remedy
|
C1754
|
It will
be set when you cannot calibrate.
|
Follow
the diagnosis code, which indicates why the
calibration has failed.
|
C2279
|
Displayed when the calibration
fails due to an internal error in
the ECU.
|
Replace
the FCM/LDW/AHB-ECU (Refer to ).
|
C2280
|
Displayed when the system detects
an implausible contrast ratio of
"black and white" portions during the
calibration.
|
Check
the calibration plate,
FCM/LDW/AHB-ECU
and the vehicle for items below, and correct it
if necessary. Then repeat the calibration
process.
- The calibration plate is installed
properly.
- The calibration plate is contaminated or
damaged.
- The FCM/LDW/AHB-ECU is
installed correctly.
- The vehicle is parked correctly (the
vehicle is not parallel to the
calibration
plate).
If you cannot calibrate the
FCM/LDW/AHB-ECU, replace it (Refer
to ).
|
C2281
|
Displayed when the system cannot
recognise the calibration plate
during the calibration.
|
C2282
|
Displayed when the system
recognises two calibration plates or more
during the calibration.
|
C2283
|
Displayed when the system detects
an implausible contrast ratio of
"white" portions during the
calibration.
|
C2284
|
Displayed when the calibration
plate is slid from the specified position
during the calibration.
|
C2285
|
Displayed when the calibration
plate is not positioned as specified.
|
C2286
|
The
input target position value for service
calibration was abnormity.
|
C2287
|
The
input distance between target to centre for
service calibration
was abnormity.
|
C2288
|
FCM/LDW/AHB-ECU
detected possibility the target overlaps,
when calibration is in progress.
|
C2289
|
Displayed when the calibration
fails due to an implausible calibration
compensation angle (pitch).
|
C2290
|
Displayed when the calibration
fails due to an implausible calibration
compensation angle (yaw).
|
C2291
|
Displayed when the calibration
fails due to an implausible calibration
compensation angle (roll).
|
|