If the air conditioner outlet temperature cannot be adjusted, the air mixing damper control
motor or the heater controller assembly (A/C-ECU) may be faulty.
|
|
- Malfunction of the air mix damper control motor
- Malfunction of the heater controller assembly (A/C-ECU)
|
|
Check that the compressor operates under the following conditions.
|
|
- Engine operation
- Air volume control dial: Maximum
- Air conditioner switch: ON
- Temperature control dial: MAX COOL
|
|
Q.
Is the check result normal?
|
|
Refer to INSPECTION PROCEDURE 6: "The A/C compressor does not work .
|
|
|
|
Check that the diagnosis code related to the air conditioner is not set.
|
|
Q.
Is the diagnosis code set?
|
|
Carry out the diagnosis code procedures. Refer to .
|
|
|
|
NO <Single-zone AUTO A/C> : Go to Step 3.
|
|
|
|
NO <Dual-zone AUTO A/C> : Go to Step 5.
|
|
|
|
Carry out the actuator test. (Refer to ).
|
|
Item No.17: As air mix damper motor
|
|
Q.
Is the check result normal?
|
|
This diagnosis is complete.
|
|
|
|
Q.
Is the check result normal?
|
|
Repair the connector(s) or wiring harness.
|
|
|
|
Carry out the actuator test. (Refer to ).
|
|
Item No.16: Dr air mix damper motor
|
|
Q.
Is the check result normal?
|
|
Q.
Is the check result normal?
|
|
Repair the connector(s) or wiring harness.
|
|
|
|
Carry out the actuator test. (Refer to ).
|
|
Item No.17: As air mix damper motor
|
|
Q.
Is the check result normal?
|
|
This diagnosis is complete.
|
|
|
|
Q.
Is the check result normal?
|
|
Repair the wiring harness.
|
|
|
|
Check that A/C outlet air temperature can be adjusted.
|
|
Q.
Is the check result normal?
|
|
This diagnosis is complete.
|
|
|
|
Replace the heater controller assembly (A/C-ECU).
|
|
|