1.Before inspection, set the
vehicle to the pre-inspection condition. 2.Turn
the ignition switch to "LOCK" (OFF)
position. 3.Connect the M.U.T.-III to the
diagnosis connector.
|
|
4.Disconnect the ventilation
hose from the air inlet fitting, and connect a vacuum gauge
to the air inlet fitting. 5.Plug the ventilation
hose. 6.Start the engine and check that idle speed
is within the standard valve. Standard value:
700 ± 100 r/min 7.Check the intake
manifold vacuum. Limit: Minimum 60
kPa 8.Turn the ignition switch to the
"LOCK" (OFF) position. 9.Remove the vacuum gauge
and then connect the vacuum hose. 10.Disconnect
the M.U.T.-III.
|