1.End
Play
Measure the end play, and if the reading
deviates from the specified valve, replace
the defective
part.
Standard value:
0.10 -
0.18 mm Limit: 0.3 mm
|
|
1.If the specified service
limit is exceeded, replace the
camshaft.
Standard
value:
Intake 50.890 mm Exhaust
51.190 mm
Standard
value:
Intake: 41.600
mm Exhaust: 41.000 mm
|
|
1.With the camshaft
supported at No.1 journal C and No.5 journal, measure the
bend at No.3
journal. If the reading exceeds the specified service limit,
replace the camshaft.
note |
The actual shaft bend is a
half of what the dial gauge reads when the
camshaft is given
one turn.
|
Standard value: Less than
0.015 mm Limit: 0.03 mm
|
|
1.Measure the oil clearance
at each journal and if the specified service limit is
exceeded,
replace the defective part.
note |
Replace the camshaft caps and
the cylinder head as an assembly if one of the
caps is unusable.
|
Standard value: 0.05
-
0.09 mm Limit: 0.15 mm
|