REMOVAL SERVICE POINTS |
<<A>> GLOW PLUG REMOVAL |
When removing the glow plug, you
may loosen using a tool up to the point where one or
more threads are left in engagement. Beyond this point,
loosen with fingers. |
|
INSTALLATION SERVICE POINTS |
>>A<< GLOW PLUG INSTALLATION |
1.Check that the glow plug,
glow plug mounting threads and plug seating of cylinder
head are dry. |
2.When installing the glow
plug, screw in one thread or more with fingers and then
tighten
with a tool. |
3.Tighten the glow plugs to
9.0 ± 1.0 N·m. |
4.Using the special tool
Angle gauge (MB991614), tighten the glow plug to a further
30° to
40°. |
>>B<< ENGINE COOLANT TEMPERATURE SENSOR INSTALLATION |
When reusing the sensor, apply the