INSPECTION




TENSION LEVER



1.Check the tension lever for evidence of cranking, flaking or other defect in the surface A that makes sliding contact with the timing chain and in the surface B that contacts the tensioner. Replace the tension lever if necessary.


TENSION LEVER-TO-TENSION LEVER SHAFT CLEARANCE



1.Measure the tension lever-to-tension lever shaft clearance.If the reading exceeds the specified service limit, replace defective part.

    Standard value: 0.06 - 0.18 mm
    Limit: 0.3 mm


CHECKING GUIDE PLATE



1.Check the guide plate for evidence of cracking, flaking or other defect in the surface A that makes sliding contact with the timing chain. Replace the guide plate if necessary.