1.Disconnect the oil feeder
control valve connector. 2.Make sure that the oil
feeder control valve generates a tick sound when the battery
voltage is applied between the connector terminals at the
oil feeder control valve side.
caution |
To prevent the coil from
burning, keep the duration of the voltage
application as short as possible.
|
|
|
1.Disconnect the oil feeder
control valve connector.
|
|
2.Measure the resistance
between the terminals of the connector at the oil feeder
control
valve.
|
|
Standard value: 6.9
- 7.9 Ω (at 20°C)
|
|
3.If the resistance deviates
from the standard value, replace oil feeder control
valve.
|