1.Immerse the thermostat in
water, and heat the water while stirring. Check the
thermostat
valve opening
temperature.
Standard
value:
82 ± 2°C
<6G7> 76.5 ± 2°C
<4M4>
|
|
2.Check that the amount of
valve lift is at the standard value when the water is at the
full-opening temperature.
note |
Measure the valve height when
the thermostat is fully closed, and use this
measurement
to compare the valve height when the thermostat
is fully open.
|
Standard
value:
Full-opening
temperature:
Amount of valve
lift:
10 mm or more <6G7,
4M41> 8.5 mm or more
<4M40>
|