SERVICE SPECIFICATIONS


Item
Standard value
Limit
Variable induction control solenoid valve coil resistance (at 20 °C) <6G75> Ω
29 - 35
-
Turbocharger supercharging pressure <4M41> kPa
178.9 - 188.2
-
Initial activation pressure of waste gate actuator (at the stroke of approximately 1 mm) kPa
4M40
Approximately 96
-
4M41
118.8 - 124.2
-
Swirl control solenoid valve coil resistance (at 20 °C) <4M41> Ω
29 - 35
-
Inlet manifold distortion of the installation surface <6G7, 4M41>mm
0.15 or less
0.20
Exhaust manifold distortion of the installation surface <6G7> mm
0.5 or less
0.90
Exhaust manifold distortion of the installation surface <4M41> mm
0.15 or less
0.20