Inspection Procedure 2: Engine Does not Start
COMMENTS ON TROUBLE SYMPTOM
If the engine does not start when the selector lever is in P or N position, the cause is probably a malfunction of inhibitor switch system, transmission control cable, engine system, torque converter or oil pump.
PROBABLE CAUSES
- Malfunction of inhibitor switch
- Malfunction of transmission control cable
- Malfunction of engine system
- Malfunction of torque converter
- Malfunction of oil pump
- Malfunction of the A/T-ECU <4M4>
- Malfunction of the engine-A/T-ECU <6G7>
|
STEP 1. M.U.T.-III diagnosis code
|
|
Either of diagnosis codes P1770 (P0705) or P1771 (P0705) is set, inhibitor switch is defective.
|
|
Q.
Are diagnosis codes P1770 (P0705) or P1771 (P0705) set?
|
|
YES diagnosis code P1770 (P0705) is set : Refer to diagnosis code P1770 (P0705): Inhibitor switch system .
|
|
|
|
YES diagnosis code P1771 (P0705) is set : Refer to diagnosis code P1771 (P0705): Inhibitor switch system .
|
|
|
|
Go to Step 2.
|
|
|
|
STEP 2. Transmission control cable check
|
|
Check the transmission control cable and inhibitor switch for installation condition.
|
|
Q.
Is the check result normal?
|
|
Go to Step 3.
|
|
|
|
Adjust the positions of the transmission control cable and inhibitor switch (Refer to ).
|
|
|
|
STEP 3. Engine system check
|
|
Q.
Is the check result normal?
|
|
Go to Step 4.
|
|
|
|
Repair the engine system.
|
|
|
|
STEP 4. A/T-ECU <4M4> or engine-A/T-ECU <6G7> replacement
|
|
(1)Replace the A/T-ECU <4M4> or engine-A/T-ECU <6G7>.
|
|
(2)Test drive the vehicle.
|
|
(3)Verify that the condition described by the customer exists.
|
|
Q.
Does a malfunction take place again?
|
|
Go to Step 5.
|
|
|
|
The inspection is complete.
|
|
|
|
STEP 5. Torque converter check
|
|
Check for damaged drive plate, incorrect installation in the input shaft (inserted at an angle) or damaged splines.
|
|
Q.
Is the check result normal?
|
|
Check the oil pump for incorrect installation, damage and etc., and replace the oil pump assembly if necessary (The oil pump cannot be disassembled).
|
|
|
|
If repair is possible, repair the damaged part. If repair is not possible because the splines on the drive plate or torque converter are damaged, replace it.
|
|
|