ABS VALVE RELAYCONTINUITY CHECK



Battery voltage
Tester connection
Specified condition
Not applied
2 - 4
Continuity exists (2 Ω or less)
2 - 5
Open circuit

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 3 to the negative battery terminal

2 - 4
Open circuit
2 - 5
Continuity exists (2 Ω or less)