INSPECTION PROCEDURE A-4: The Central Door Locking System does not function by using the Door Key Cylinder. <Using SWS Monitor>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.





COMMENT ON TROUBLE SYMPTOM


If the central door locking system does not work normally only when the door key cylinder is operated, the door key switch or the ETACS-ECU may be defective.

POSSIBLE CAUSES




DIAGNOSIS PROCEDURE


Step 1. ETACS switch data by using the SWS monitor


Check the ETACS-ECU signal, which is related to the driver’s key cylinder operation.

Item No.
Item name
Normal condition
Item 26
Centre door lock switch
from OFF to ON
Item 27
Centre door unlock switch
from ON to OFF
OK: Normal conditions are displayed for all the items.

Q. Are the check result normal?

Go to Step 2.

Refer to GROUP 54A, inspection procedure C-16 "The signal from the central door lock switch (incorporated with the power windows main switch) is not received <LH drive vehicles> or <RH drive vehicles>."

Step 2. Retest the system.


Check that the central door locking system works normally by the driver’s key cylinder operation.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00, How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.