INSPECTION PROCEDURE B-2: Keyless Entry Hazard Lamp Answerback Function or The Room Lamp Answerback Function does not Work Normally.



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.


COMMENTS ON TROUBLE SYMPTOM


If the hazard warning lamp and the room lamp work normally, the ETACS-ECU may be defective.
Alternatively, it is possible that the keyless entry hazard lamp answerback function was disabled by the customise function.

POSSIBLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Customise function by using the SWS monitor.


Check that "Hazard answer-back operation" is set to other than "Without function" by using the SWS monitor customisation function.

Q. Is the check result normal?

Go to Step 2.

Set "Hazard answer-back operation" to other than "Without function" by using the SWS monitor customisation function (Refer to ).

STEP 2. Check the operation of the hazard warning lamp.


Check that the hazard warning lamp illuminate normally.

Q. Is the check result normal?

Go to Step 3.

Refer to GROUP 54A, inspection procedure "The hazard warning lamps do not illuminate <Not using SWS monitor> or <Using SWS monitor>."

STEP 3. Check the operation of the room lamps.


Check that the room lamps illuminate normally.

Q. Is the check result normal?

Go to Step 4.

Refer to GROUP 54A, inspection procedure 1 "The interior lamps (room lamp, rear personal lamps, door lamps, luggage compartment lamp, key illumination lamp) does not illuminate or extinguish normally <Not using SWS monitor> or <Using SWS monitor>."

STEP 4. Check the operation of the keyless entry system.


If the keyless entry system is operated, check that the doors can be locked and unlocked normally.

Q. Is the check result normal?

Go to Step 5.

Refer to inspection procedure A-1 "Keyless entry system does not work <Not using SWS monitor>" or inspection procedure B-1 "Keyless entry system does not work <Using SWS monitor>."

STEP 5. ECU check by using the SWS monitor


Check that the power supply and earth lines to the ETACS-ECU and the SWS communication lines are normal.

ECU TO BE CHECKED
OK: "OK" is displayed on the "ETACS ECU" menu.

Q. Is the check result normal?

Go to Step 6.

Refer to GROUP 54C, Inspection Procedure 2 "Communication with ETACS-ECU is not possible ."

STEP 6. Retest the system.


Check that the keyless entry hazard lamp answerback function or the room lamp answerback function work normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00, How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.