CUSTOMISATION FUNCTION


Using M.U.T.-III and SWS monitor adjusts the following function. The programmed information is held even when the battery is disconnected.
Item No.
Items shown on M.U.T.-III screen
Item
Adjustment item shown on M.U.T.-III screen
Adjusting content
24
Timer relock after unlocking
Timer lock time after executing the keyless entry unlock
30sec.
30 seconds (the initial condition)
60sec.
1 minute
120sec.
2 minutes
180sec.
3 minutes
40
Hazard answer-back operation
Keyless entry hazard answer-back flashing pattern adjustment function
LOCK:1/UNLOCK:2
LOCK: Flash once, UNLOCK: Flash twice (Initial setting)
LOCK:1/UNLOCK:0
LOCK: Flash once, UNLOCK: No flash
LOCK:0/UNLOCK:2
LOCK: No flash, UNLOCK: Flash twice
LOCK:2/UNLOCK:1
LOCK: Flash twice, UNLOCK: Flash once
LOCK:2/UNLOCK:0
LOCK: Flash twice, UNLOCK: No flash
LOCK:0/UNLOCK:1
LOCK: No flash, UNLOCK: Flash once
Without function
No flashing
note Adjustment items other than the above will also be shown on M.U.T.-III screen. However, they cannot be reconfigured.