INSPECTION PROCEDURE B-5: The Power Window Timer Function does not work Normally. <Using SWS Monitor>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.


OPERATION


The ETACS-ECU operates this function in accordance with the input signals below.


COMMENTS ON TROUBLE SYMPTOM


If the power window timer function does not work normally, these input signal circuit(s) or the ETACS-ECU may be defective.

POSSIBLE CAUSES




DIAGNOSTIC PROCEDURE


STEP 1. Check the power window main switch.


Check that all of the front passenger’s and rear door power windows can operate by means of the power window main switch.

Q. Is the check result normal?

Go to Step 2.

Refer to inspection procedure B-1 "Power windows do not work at all <Not using SWS monitor> or <Using SWS monitor>."

STEP 2.ECU check by using the SWS monitor


Check that the power supply and earth lines to the ETACS-ECU and the SWS communication lines are normal.

ECUS TO BE CHECKED
OK: "OK" are displayed for all the items

Q. Is the check result normal?

Go to Step 3.

Refer to GROUP 54C, Inspection Procedure A-3 "Communication with ETACS-ECU is not possible ."

STEP 3. SWS monitor data list


Check the SWS communication signal, which are related to the power window timer function.
<Selected item> ETACS ECU
Item No.
Item name
Normal condition
Item 30
IG SW(IG1)
OFF
Item 32
DR DOOR SW
from OFF to ON
OK: Normal conditions are displayed for all the items

Q. Are the check result normal?

YES <Normal conditions are displayed for all the items.> : Go to Step 4.

NO <Normal condition is not displayed for item No.30.> : Refer to GROUP 54A, inspection procedure C-2 "The ignition switch (IG1) signal is not received ."

NO <Normal condition is not displayed for item No.32.> : Refer to GROUP 54A, inspection procedure C-5 "The driver’s door switch signal is not received <LH drive vehicles> or <RH drive vehicles>."

STEP 4. Retest the system.


Check that the power window timer function works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00, How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.