Inspection Procedure 6: Interior Lamp Automatic Shutoff Function does not Work Normally. <Vehicles with Keyless Entry System>



caution Whenever the ECU is replaced, ensure that the input and output signal circuits are normal.


COMMENTS ON TROUBLE SYMPTOM


The ETACS-ECU operates the interior lamp automatic-shutdown function in accordance with the input signals below.

If this function does not work normally, these input signal circuit(s) or the ETACS-ECU may be defective. Note that this function can be disabled/enabled by the adjustment function (default setting; enabled).

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Customize function by using the SWS monitor


Use the SWS monitor customisation function to confirm that "Room lamp auto-cut" is set to other than "Without function" (one of the settings below).

Q. Is the check result normal?

Go to Step 2.

Use the SWS monitor customisation function to confirm that "Room lamp auto-cut" is set to other than "Without function" (Refer to ).

STEP 2. ECU check by using the SWS monitor


Check that the power supply and earth lines to the ETACS-ECU and the SWS communication lines are normal.

ECU TO BE CHECKED
OK: "OK" is displayed on the "ETACS ECU" menu.

Q. Is the check result normal?

Go to Step 3.

Refer to GROUP 54C - Trouble Symptom Chart .

STEP 3. SWS monitor data list.


Check the input signals below, which are related to the interior lamp automatic-shutdown function.
<Selected item> ETACS ECU
Item No.
Item name
Normal condition
Item 30
IG SW(IG1)
OFF
Item 31
IG SW(ACC)
OFF
Item 32
FRONT DOOR SW
ON
OK: Normal condition is displayed.

Q. Is the check result normal?

YES (Normal conditions are displayed for all the items) : Go to Step 4.

NO (Normal condition is not displayed for item No.30) : Refer to ETACS - Input Signal Chart .

NO (Normal condition is not displayed for item No.31) : Refer to ETACS - Input Signal Chart .

NO (Normal condition is not displayed for item No.32) : Refer to ETACS - Input Signal Chart .

STEP 4. ETACS switch data by using the SWS monitor


Check the ETACS-ECU signals related to the operation of the interior lamp automatic-shutdown function.

Item No.
Item name
Normal condition
Item 05
Passenger’s door switch
from OFF to ON

Item No.
Item name
Normal condition
Item 07
Rear and back gate door switch
from OFF to ON

Item No.
Item name
Normal condition
Item 41
Rear door (right side) switch
from OFF to ON

Item No.
Item name
Normal condition
Item 42
Rear door (left side) switch
from OFF to ON
OK: Normal conditions are displayed for all the items.

Q. Is the check result normal?

Go to Step 5.

Refer to ETACS - Input Signal Chart .

STEP 5. Pulse check


Check the input signals below, which are related to the room lamp automatic-shutdown function.
System switch
Check condition
Interior lamp loaded signal
When a load is applied through fuse No.18
OK: The M.U.T.-III sounds or the voltmeter needle fluctuates.

Q. Is the check result normal?

Go to Step 6.

Refer to ETACS - Input Signal Chart .

STEP 6. Retest the system.


Check that the interior lamp automatic-shutdown function works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.