VACUUM ACTUATOR CHECK <4D56>



1.Pull off the vacuum hose (yellow stripe) connected to the vacuum actuator.

2.Connect a manual vacuum pump to the nipple of the vacuum actuator.
3.Check to be sure that the vacuum actuator rod starts to contact when 8 kPa of negative pressure is applied, and that the rod contracts to its full stroke when 12 kPa of negative pressure is applied.
4.
caution Be careful, when connecting the vacuum hose not to damage it.
Disconnect the manual vacuum pump from the vacuum actuator, and connect the vacuum hose (yellow stripe) to the vacuum actuator.
5.Start the engine and let it run at idle. Then cover the end of the vacuum hose (yellow stripe) with a finger and check the negative pressure when the A/C switch is turned on and off.
A/C switch
Negative pressure at hose end
OFF
No
ON
Yes