Code No. P0132: Oxygen Sensor (front) Circuit High Voltage




OPERATION




FUNCTION




TROUBLE JUDGEMENT


Check Conditions
Judgement Criterion

FAIL-SAFE AND BACKUP FUNCTION




PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. M.U.T.-III data list



  • Data list reference table (Refer to ).

    1. Item AC: Oxygen sensor (front)

Q. Are the check results normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Go to Step 2.

STEP 2. Check of short circuit in O2FL line between oxygen sensor (front) connector and engine-ECU connector.


Q. Is the check result normal?

Go to Step 3.
Repair the connector(s) or wiring harness.

STEP 3. Check of short circuit in OFLE line between oxygen sensor (front) connector and engine-ECU connector.


Q. Is the check result normal?

Go to Step 4.
Repair the connector(s) or wiring harness.

STEP 4. M.U.T.-III data list



  • Data list reference table (Refer to ).

    1. Item AC: Oxygen sensor (front)

Q. Is the check result normal?

Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Replace the engine-ECU.