SERVICE SPECIFICATIONS



<4D5>
Item
Standard value
Limit
Turbocharger supercharging pressure kPa
181 - 221
-
Initial activation pressure of waste gate actuator (at the stroke of approximately 1 mm) kPa
127.1 - 139.7
-
Inlet manifold distortion of the installation surface mm
0.15 or less
0.20
Exhaust manifold distortion of the installation surface mm
0.15 or less
0.7